Products
Products
High voltage parallel (series) capacitor bank
The SDrHVM shunt capacitor bank is installed in the power grid, which is mainly used to compensate the reactive power of the system, improve the power factor, and also help stabilize the voltage and reduce the network loss. Improving the power factor also means increasing the power transmission capacity and enhancing the power flow control. SDrHVM frame type capacitor bank, configurable inner fuse, outer fuse, no fuse capacitor unit. Its main advantages are compact design, small footprint and easy maintenance.
Product Description
Product overview
The SDrHVM shunt capacitor bank is installed in the power grid, which is mainly used to compensate the reactive power of the system, improve the power factor, and also help stabilize the voltage and reduce the network loss. Improving the power factor also means increasing the power transmission capacity and enhancing the power flow control.
SDrHVM frame type capacitor bank, configurable inner fuse, outer fuse, no fuse capacitor unit. Its main advantages are compact design, small footprint and easy maintenance.
Application areas
It is mainly used on the 3 ~ 35kV bus of the total step-down substation of large and medium-sized enterprises in petrochemical, metallurgy, mining, building materials, water supply and drainage, power grid and other industries.
Standard
IEC 60871-1:2014, gb/t 11024.1-2019,GB 50227-2017, gb/t 30841-2014, dl/t 604-2020
Operating conditions
· Rated voltage: 3kV, 6kV, 10kV, 27.5kV, 35kV, 63kV;
· Rated frequency: 50/60Hz
· Rated power: 150~60000kVar
· Reactivity rate: 0.1~1%;4.5 ~ 6%;12% ~ 13%
· Operating temperature:-40 ℃ ~ 55 ℃;
· Storage temperature:-45 ℃ ~ 70 ℃;
· Relative humidity: monthly average is not more than 90% (25 ℃), no condensation;
· Altitude:<2000m a.s.l.(≤ 5000m optional);
· Seismic intensity: ≤ 8 degrees.
Design
Structural design: ① Frame type ② Cabinet type ③ Fence type ④ Collective type.
Arrangement: three-phase or split-phase arrangement. When the voltage exceeds 35KV, the capacitor device adopts three-phase arrangement.
Connection mode: single-star and double-star connection, multi-segment series connection.
Protection mode: open triangle, neutral point unbalanced current (voltage) protection, differential voltage protection, etc;
Main equipment: high-voltage shunt capacitors, reactors, special fuses for capacitors, zinc oxide arresters, discharge coils, etc. Isolating switches or grounding switches can be added according to user requirements.
Frame material: The surface of the angle steel frame is electrostatically sprayed, which is beautiful, strong and durable.

Detailed technical parameters and product models, contact us!