Products
Products
Medium voltage automatic reactive power compensation device
According to the voltage and reactive power of the power supply bus, the SDrHM series high-voltage automatic reactive power compensation device (APFC) adopts the power factor controller to automatically detect the active and reactive power of the system in real time, automatically switches the capacitor bank, and tracks the change of the load for reactive power compensation, thus providing the power factor, improving the power supply quality and reducing the power loss.
Product Description
According to the voltage and reactive power of the power supply bus, the SDrHM series high-voltage automatic reactive power compensation device (APFC) adopts the power factor controller to automatically detect the active and reactive power of the system in real time, automatically switches the capacitor bank, and tracks the change of the load for reactive power compensation, thus providing the power factor, improving the power supply quality and reducing the power loss.
Application areas
Mainly used in metallurgy, mining, building materials, petrochemical, water supply and drainage and other industries of large and medium-sized enterprises load fluctuations in the substation or distribution room, can make the shunt capacitor play a higher compensation effect, and avoid over compensation or under compensation, to ensure that the system required reactive power to achieve balance.
Standard
IEC 60871-1:2014, gb/t 11024.1-2019,GB 50227-2017, gb/t 30841-2014, dl/t 604-2020
Operating conditions
Rated voltage: 3kV, 6kV, 10kV;
Rated frequency: 50/60Hz;
Cutting mode; manual and automatic
CITCH SWITCH: VACUUM CONTACTOR OR CIRCUIT BREAKER
Reactor rate: 6% or 12%, according to user requirements
Structure: cabinet structure, can be customized according to user requirements
Shell color: RAL7035, according to user requirements
Operating temperature:-25 ℃ ~ 55 ℃;
Storage temperature:-45 ℃ ~ 70 ℃;
Relative humidity: monthly average is not more than 90% (25 ℃), no condensation;
Altitude:<2000m a.s.l.(≤ 5000m optional);
Seismic intensity: ≤ 8 degrees.
Design
The device is equipped with reactive power automatic compensation, automatically tracking the change of reactive load, switching capacitor bank, improving power factor and improving power quality. Harmonic suppression function, series reactor can be equipped according to the harmonic situation given on site to form LC loop to suppress harmonics; Perfect capacitor bank protection includes overvoltage protection, undervoltage protection, overcurrent protection, zero sequence voltage protection and unbalanced voltage protection of capacitor branch.
Technical parameters
Detailed technical parameters and product models, contact us!
Previous Page
Next Page
Previous Page
Next Page