product center

>
>
>
MV&HV Static Var Generator

MV&HV Static Var Generator

MV&HV Static Var Generator

The principle of the HV SVG is very similar to that of Active Power Filter, as demonstrated in the picture below. When the load is generating inductive or capacitive current, it makes load current lagging or leading the voltage. SVG detects the phase angle difference and generates leading or lagging current into the grid, making the phase angle of current almost the same as that of voltage on the transformer side, which means fundamental power factor is unit. Splend Electric series HV SVG is also capable of correcting load imbalance.
没有此类产品
Product description

SDHG Introduction

The principle of the HV SVG is very similar to that of Active Power Filter, as demonstrated in the picture below. When the load is generating inductive or capacitive current, it makes load current lagging or leading the voltage. SVG detects the phase angle difference and generates leading or lagging current into the grid, making the phase angle of current almost the same as that of voltage on the transformer side, which means fundamental power factor is unit.

Splend Electric series HV SVG is also capable of correcting load imbalance.

 

Application field: rail transit: traction locomotive; Power generation: wind farms, photovoltaic power plants, thermal power plants; Metallurgy: electric arc furnace, refining furnace, rolling mill; Power transmission and transformation: substation;

 

Rated voltage

6kV10kV27.5kV35kV

Rated frequency

50/60Hz

Rated capacity

±1~±100Mvar

Multifunctional

Reactive power and imbalance compensation

Excellent reactive compensation

High speed, Precise (-0.99≤Cosφ≤0.99), Step-less, Bi-directional (capacitive and inductance) compensation

Excellent imbalance correction

Both negative and zero sequence, mitigates neutral current

 

Wide input voltage & frequency range, adapts to tough electrical environment

loss&efficiency

Low thermal loss (≤3% of rated SVG capacity), efficiency ≥ 97%

High stability

Infinite impedance to grid, avoids harmonic resonance problem

 