According to the voltage and reactive power of the power supply bus, the SD-BML series low voltage reactive power compensation device (APFC) adopts the power factor controller to automatically detect the active and reactive power of the system in real time, automatically switches the capacitor bank, and tracks the change of the load for reactive power compensation, thus providing the power factor, improving the power supply quality and reducing the power loss.
Product Description
According to the voltage and reactive power of the power supply bus, the SD-BML series low voltage reactive power compensation device (APFC) adopts the power factor controller to automatically detect the active and reactive power of the system in real time, automatically switches the capacitor bank, and tracks the change of the load for reactive power compensation, thus providing the power factor, improving the power supply quality and reducing the power loss.
Use occasion
· Automatic reactive power compensation, can be installed directly;
· It is used for centralized compensation of reactive power in three-phase power grid with serious harmonic pollution;
· Upper limit of harmonic pollution in use: U3 max.0.5%, U5 max.5%,U7 max.4%;
Standard
Technical standard: EN60439-1, EN60831-1, IEC439-1, GB/T 15576-2020
Operating conditions
Rated voltage: 230V-690V
Rated frequency: 50Hz/60Hz
Withstand voltage test: according to the standard
Cooling method: forced air cooling
Ambient temperature:-15 to 50°C (65°C high)
Altitude:<2000m a.s.l.(≤ 5000m optional)
Relative humidity: 10…95% (no condensation allowed)
Installation conditions: indoor installation. For outdoor installation, please contact us
Design
SD-MV®Reactive power compensation and harmonic control integrated drawer module
Fully automatic control, contactor switching
Capacitor UN = 480V, Overcurrent Capability: 1.5In
Single cabinet kit, IP00, without cabinet body.
Warranty period: 30 months
Reactivity rate: 5.67%,7%,8%,14%
Rated voltage: 230~690V (max. + 10% within 8 hours per day),50/60Hz
Protection grade: IP20 or IP00; For IP54, please contact us.
Temperature rating: -20/B (24 hours average temperature 35 ℃). For higher, welcome to inquire.
Modular components
· High load, dry type, low loss, self-healing capacitor, with over pressure protection device;
· Vertical busbar system with low voltage fuse protection;
· Special contactor;
· Filter reactor, with temperature monitoring, low loss, full vacuum impregnation;
· Temperature monitoring;