Products
Products
SDrH High Voltage Iron Core Dry Series (Filter) Reactor
High-voltage reactive power compensation reactor, also known as tuning reactor or filter reactor, is generally used in series with the capacitor, applied to the power reactive power compensation system, to achieve the target induced current, with improve the power factor and suppress the wipe wave current and other functions. The product is widely used in power grid, metallurgy, petrochemical and other fields, as well as urban network substation, underground substation and microcomputer control substation and other places.
Product Description
high voltage reactive power compensation reactor
High-voltage reactive power compensation reactor, also known as tuning reactor or filter reactor, is generally used in series with the capacitor, applied to the power reactive power compensation system, to achieve the target induced current, with improve the power factor and suppress the wipe wave current and other functions. The product is widely used in power grid, metallurgy, petrochemical and other fields, as well as urban network substation, underground substation and microcomputer control substation and other places.
Standard
Compliance Follow: EN60076-6
Operating conditions
Rated voltage: 3kV to 35kV
Rated frequency: 50Hz/60Hz
Withstand voltage test: according to the standard
Cooling method: natural air
Ambient temperature:-25 to 50 ℃
Altitude: ≤ 1000m a.s.l. (≤ 5000m optional)
≤ Humidity: 95%
Protection grade: IP00 indoor installation
Allowable harmonic content: U3 = 0.5%;U5=5%;U7 = 5%.
Design
Inductance tolerance: 0/+ 10% (or +/-3% optional)
Reactivity rate: 5%-14%
Linearity: 1.55-2.2In
Insulation grade: H
Design: single-phase or three-phase, dry core, multi-air gap
Coil Material: Copper/Aluminum
Temperature control switch: 135 ℃, normally closed (optional)
Outlet mode: copper bar
high voltage current limiting reactor
High-voltage current-limiting reactors, also known as surge suppression reactors or damping reactors, are usually used in systems to protect equipment from surge short-circuit currents, and have the function of limiting peak inrush currents in switches.
Standard
Compliance Follow: EN60076-6
Operating conditions
Rated voltage: 3kV to 35kV
Rated frequency: 50Hz/60Hz
Rated current: 25A-3200A
Withstand voltage test: according to the standard
Cooling method: natural air
Ambient temperature:-25 to 50 ℃
Altitude: ≤ 1000m a.s.l.(≤ 5000m optional)
≤ Humidity: 95%
Protection grade: IP00 indoor installation
Design
Inductance tolerance: + 20% (or + 10% optional)
Insulation grade: H
Design: single-phase, dry core
Coil Material: Copper/Aluminum
Outlet mode: copper bar