底部版权

 

Splend Electric (Beijing) Co., Ltd

Tel:+86  10  50842888               
Fax:+86  10  50842886
E-mail:
splend@splendpower.com

Http:www.splendpower.com

Add:52A, No.17 Jing Sheng South 4th Street, Zhongguancun Science and

          Tec hnology Park, Tongzhou District, Beijing-China

 

Mobile phone

website

WeChat two-dimensional code

 

                             Copyright: Splend Electric (Beijing) Co., Ltd.   京ICP备10023425号

product center

>
>
>
Medium Voltage Reactors

Medium Voltage Reactors

Medium Voltage Reactors

The products, also called detuned reactors or filter reactors, are generally used in series with capacitors in PFC system, in order to reach its target induced current. It possesses the functions of increasing power factors and limiting harmonic current.
没有此类产品
Product description

Medium Voltage Reactors for PFC

 

The products, also called detuned reactors or filter reactors, are generally used in series with capacitors in PFC system, in order to reach its target induced current. It possesses the functions of increasing power factors and limiting harmonic current.

 

Standard

ln compliance with:EN60076-6UL1446

Approval marks: EAC CE

 

Operating condition

Rated voltage:3kV to 35kV

Rated frequency:50Hz/60Hz

Dielectric test :According to the standard

Cooling method:Natural air

Ambient temperature :25 to + 50

Elevation above sea level :1000m a.s.l. (5000m optional)

Maximum humidity:95%

Protection class:IP00 indoor mounting

Permitted harmonic content:U3=0.5% ;U5=5%;U7 = 5%

 

Design

lnductance tolerance: 0/+5%(or +/-3% as requested)

Blocking factor: 5%-14%

Linearity: 1.55-2.2In

lnsulation class: H(UL approved resin)

Design method: Single phase or three phase, dry type iron core,multiple air gap

Winding material: Copper/Aluminum

Thermal protection: 135normally closed switch (optional)

Terminals: Copper bar

Medium Voltage Current Limiting Reactors

The products, also called inrush reactors or damping reactors, are generally used in the system to protect the equipments free from surging short circuit current. lt possesses the functions of limiting peak inrush currents in the switching.

 

Standard

ln compliance with:EN60076-6UL1446

Approval marks: EAC CE

 

Operating condition

Rated voltage:3kV to 35kV

Rated frequency:50Hz/60Hz

Rated current:25A-3200A

Dielectric test :According to the standard

Cooling method:Natural air

Ambient temperature :25 to + 50

Elevation above sea level :1000m a.s.l. (5000m optional)

Maximum humidity:95%

Protection class:IP00 indoor mounting

 

Design

lnductance tolerance:+20%(or +10% as requested)

lnsulation class: H(UL approved resin)

Design method: Single phase, dry type iron core

Winding material: Copper/Aluminum

Terminals: Copper bar

Corresponding parameter set not found, please add it in property template of background
暂未实现,敬请期待
暂未实现,敬请期待